FT100 Torch Ignitor
Automatic Oxyfuel Torch Ignitor
When the FT100 Torch Ignitor is energized, the fuel gas solenoid opens, allowing gas to flow and to be lit with a high voltage arc (approximately 6500 volts) at the nozzle. To assure ignition of the FT100's flame, sparking will continue in four second duration. The flame is aimed along a 45o angle at the torch tip. The ignition flame then lights the low preheat fuel gas and oxygen stream exiting from the machine torch's tip.
Key Features:
- Provides dependable torch ignition under most conditions including wind.
- Self-contained lighting system reliably starts ignitor, even with low pressure natural gas.
- Each torch station has a high voltage transformer and preheat fuel gas solenoid for maximum reliability.
- Individual programmable station selection in the CNC mode automates cutting process for high productivity.
- Available on the Platemaster II, Titan III, MPC2000, and TMC4500 DB machine models.